ICAN Intelligent J-Box

ICAN Intelligent J-Box
  • ICAN Intelligent J-Box
  • ICAN Intelligent J-Box

Cardinal’s diagnostic and monitoring system, iCan offers analog to digital conversion system for all analog load cell systems, new or retrofit. Real-time load cell diagnostics identifies load cell problems before they cause inaccurate weighing, so scale downtime is minimized. iCan works with any analog load cell; you’re not tied to a single source! Each iCan junction box supports up to eight load cells. For ten or more cells, interconnecting cable will be provided. NTEP legal-for-trade certified.

  • Model
  • Description
  • Quote
  • ModelICAN4P
  • DescriptioniCan J-Box, 4 Cell, Fiber Optic, Plastic
  • ModelICAN6P
  • DescriptioniCan J-Box, 6 Cell, Fiber Optic, Plastic
  • ModelICAN8P
  • DescriptioniCan J-Box, 8 Cell, Fiber Optic, Plastic
  • ModelICAN10P
  • DescriptioniCan J-Box, 10 Cell, Fiber Optic, Plastic
  • ModelICAN12P
  • DescriptioniCan J-Box, 12 Cell, Fiber Optic, Plastic
  • ModelICAN14P
  • DescriptioniCan J-Box, 14 Cell, Fiber Optic, Plastic
  • ModelICAN4G
  • DescriptioniCan J-Box, 4 Cell, Fiber Optic, Glass
  • ModelICAN6G
  • DescriptioniCan J-Box, 6 Cell, Fiber Optic, Glass
  • ModelICAN8G
  • DescriptioniCan J-Box, 8 Cell, Fiber Optic, Glass
  • ModelICAN10G
  • DescriptioniCan J-Box, 10 Cell, Fiber Optic, Glass
  • ModelICAN12G
  • DescriptioniCan J-Box, 12 Cell, Fiber Optic, Glass
  • ModelICAN14G
  • DescriptioniCan J-Box, 14 Cell, Fiber Optic, Glass
  • ModelICANW
  • DescriptioniCan Wireless Transceiver
  • ModelISITE-NET-KIT
  • DescriptioniSite Ethernet Kit
  • ModelISITE-TEL-KIT
  • DescriptioniSite Modem Kit
  • Option
  • Description
  • Quote

No options have been added for this product.

  • Specification
  • Description
  • SpecificationPower Requirements:
  • Description115 to 230 VAC 50/60 Hz at 1 ampere per junction box
  • SpecificationTemperature Range (Compensated):
  • Description-13 to 104 ˚F (-25 to +40 ˚C)
  • SpecificationJunction Box Connections:
  • Description2 AC Power, 8 load cell inputs, 2 fiber optic or copper wire
  • SpecificationJunction Box Dimensions:
  • Description17 in W x 9 1/2 in D x 3 3/8 in H (432mm x 241mm x 88mm)
  • SpecificationSample Rate:
  • Description1 to 50 samples per second, selectable
  • SpecificationLoad Cells:
  • DescriptionUp to eight 350-ohm strain gauge load cells per box
  • SpecificationLoad Cell / Scale Capacity:
  • DescriptionThirty-two 350-ohm load cells among up to 3 scales (8 load cells per box, maximum of four boxes)
  • SpecificationExcitation Voltage:
  • Description12 VDC
  • SpecificationSensitivity (Non-Commercial):
  • Description0.15 uV/e
  • SpecificationSensitivity (NTEP):
  • Description0.3 uV/e (Class III/IIIL)
  • SpecificationSensitivity (Canada):
  • Description0.3 uV/e (Class III/IIIHD)
  • SpecificationSensitivity (OIML):
  • Description1.2 uV/e (Class III)
  • SpecificationScale Divisions (Non-Commercial):
  • Description240,000
  • SpecificationScale Divisions (NTEP):
  • Description10,000 (Class III/IIIL)
  • SpecificationScale Divisions (Canada):
  • Description10,000 (Class III/IIIHD)
  • SpecificationScale Divisions (OIML):
  • Description10,000 (Class III)
  • SpecificationInternal Resolution:
  • Description1 part in 16,777,216
  • SpecificationTransmission Distance:
  • DescriptionPlastic Fiber: Up to 300 feet (30 foot minimum); Glass Fiber: Up to 5,000 feet; Copper Wire: Up to 1,000 feet